Temperature
No |
Item |
Range |
40 |
Autoclave * |
121 oC |
41 |
Block Calibrator * |
-30 - 800 oC |
42 |
Cold room |
-25 - 0 oC |
43 |
Dial Thermometer * |
-30 - 500 oC |
44 |
Digital Thermometer * |
-30 - 1000 oC |
45 |
Electric Oven*/Incubator(3/9 point) * |
20 - 300 oC |
46 |
High Temperature oven |
400 - 1000 oC |
47 |
Industrial Washing Machine/Dryer |
30 - 200 oC |
48 |
Laboratory Furnace * |
200 - 1000 oC |
49 |
Liquid bath* |
-60 - 600 oC |
50 |
Liquid in glass Thermometer * |
-40 - 500 oC |
51 |
Platinum Resistance Thermometers * |
- 30 - 600 oC |
52 |
Surface temperature measurement |
0 - 300 oC |
53 |
Temperature Indicator andcontroller * |
0 - 800 oC |
54 |
Temperature profile in Retort |
121 oC |
55 |
Temperature recorder |
- 30 - 1000 oC |
56 |
Thermocouple * |
-30 - 1000 oC |
57 |
Water bath * |
0 - 100 oC |
Parameter - Temperature |
|
1 |
Liquid in glass Thermometer – 40 to 100 0C |
2 |
Liquid in glass Thermometer - 10 to 11 0C |
3 |
Liquid in glass Thermometer - 0 to 110 0C |
4 |
Liquid in glass Thermometer - 0 to 200 0C |
5 |
Liquid in glass Thermometer- 0 to 300 0C |
6 |
Liquid in glass Thermometer - 0 to 500 0C |
7 |
Liquid in glass Thermometer Min/Max 0 to 100 0C |
8 |
Liquid in glass Thermometer Wet/Dry 0 to 100 0C |
9 |
Digital thermometer with a sensor -30 to 150 0C |
10 |
Digital thermometer with a sensor -30 to 250 0C |
11 |
Digital thermometer with a sensor 0 to 500 0C |
12 |
Digital thermometer with a sensor 0 to 700 0C |
13 |
Digital thermometer with a sensor 0 to 800 0C |
14 |
Digital thermometer without a senor -30 to 200 0C |
15 |
Digital thermometer without a sensor -30 to 500 0C |
16 |
Digital thermometer without a sensor 0 to 800 0C |
17 |
Digital thermometer without a sensor 0 to 1200 0C |
18 |
Temperature recorder with a sensor-single channel -30 to 150 0C |
19 |
Temperature recorder with a sensor Two channel -30 to 150 0C |
20 |
Temperature recorder with a sensor - 3 to 6 channels -30 to 150 0C |
21 |
Temperature recorder with a sensor single channel -30 to 250 0C |
22 |
Temperature recorder with a sensor Two channel - 30 to 250 0C |
23 |
Temperature recorder with a sensor - 3 to 6 channels -30 to 250 0C |
34 |
Temperature recorder with a sensor 12 channels |
25 |
Temperature recorder with a sensor Single channel 0 to 700 0C |
26 |
Temperature Controller/Transmitter 0 to 100 0C |
27 |
Temperature Controller/Transmitter 0 to 250 0C |
28 |
Temperature Controller/Transmitter 0 to 400 0C |
29 |
Temperature Controller/Transmitter 0 to 600 0C |
30 |
Temperature Controller/Transmitter 0 to 700 0C |
31 |
Temperature Controller/Transmitter (with sensor) Above 500 0C |
32 |
Thermocouple (Industrial type) -30 to 100 0C |
33 |
Thermocouple (Industrial Type) 0 to 250 0C |
34 |
Thermocouple (Industrial Type) 0 to 500 0C |
35 |
Thermocouple (Industrial Type) 0 to 1000 0C |
36 |
Thermocouple (Standard type) -30 to 100 0C |
37 |
Thermocouple (Standard type) -30 to 250 0C |
38 |
Thermocouple (Standard type) 0 to 500 0C |
39 |
Thermocouple (Standard type) 0 to 1000 0C |
40 |
RTD -30 to 200 0C |
41 |
RTD -30 to 300 0C |
42 |
RTD -30 to 500 0C |
43 |
PRT -30 to 100 0C |
44 |
PRT -30 to 200 0C |
45 |
PRT -30 to 300 0C |
46 |
PRT -30 to 500 0C |
47 |
PRT -30 to 600 0C |
48 |
Dial thermometer -30C to 100 0C |
49 |
Dial thermometer -30 to 200 0C |
50 |
Dial thermometer -30 to 300 0C |
51 |
Dial thermometer -30 to 500 0C |
52 |
Laboratory Oven – (9sites, Single test point) - 50 to 250 0C |
53 |
Laboratory Oven - (3sites Single test point) 50 to 250 0C |
54 |
Belt type oven |
55 |
Box type oven |
56 |
Oven (humidity& Temperature) |
57 |
Incubator (Humidity & Temperature) |
58 |
Deck Oven |
59 |
Laboratory oven (3 sites, two test points) 50 to 250 0C |
60 |
Laboratory Oven (3sites, three test points) 50 to 250 0C |
61 |
Laboratory incubator (9sites, Single test point) 20 to 70 0C |
62 |
Laboratory incubator (3sites, Single test point) 20 to 70 0C |
63 |
Laboratory incubator (3sites, two test points) 20 to 700C |
64 |
Laboratory incubator (3sites, three test points) 20 to 70 0C |
65 |
Laboratory Muffle Furnace 50 to 300 0C |
66 |
Laboratory Muffle Furnace 50 to 600 0C |
67 |
Laboratory Muffle Furnace 50 to 1000 0C |
68 |
Auto clave 121 0C |
69 |
Autoclave with Pressure Gauge 121 0C |
70 |
Autoclave load test 121 0C |
71 |
Water Bath (single test point) - 0 to 100 |
72 |
Water Bath (Two test points) -0 to 100 0C |
73 |
Water Bath (Three test points) 0 to 100 0C |
74 |
Block Dry Well Calibrator -30 to 400 0C |
75 |
Block Dry Well Calibrator -30 to 600 0C |
76 |
COD/BOD Reactors upto 200C |
77 |
Industrial Washing Machine - 30 to 120 0C |
78 |
Industrial Drying Machine upto 100 0C |
79 |
Humidity Meter/Hygrometer 20% to 7% |
80 |
Fusing Machine/Heat Seal-Only temperature 30 to 200 0C |
81 |
Fusing machine/Heat Seal-Temp & Pressure 31 to 200 0C |
82 |
IR Thermometer 50 to 500 0C |
83 |
Industrial Oven with load (Box type-large) - 400 to 1000 0C |
84 |
Industrial Oven with load (Belt type & Small Box type)- 400 to 1000 0C |
85 |
Retort without cans - 121 0C |
86 |
Retort Temperature profile with cans 121 0C |
87 |
Fabric Inspection Machine |
The services provided are ISO 17025 accredited.
All non accredited calibration services are provided with international traceability
Any equipment not listed will be undertaken for calibration with international traceability on special request
Last Updated on Tuesday, 26 March 2019 10:49